{"title":"Paint Booth Fans : GFA \u0026 ATA Model","description":"","products":[{"product_id":"30-tube-axial-ata-paint-booth-fan-8860-15810-cfm","title":"Global Finishing Solutions ATA-30-030 30 Inch Tube Axial Paint Booth Fan Less Motor","description":"\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eATA-30\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e32.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e33.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e22.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-30-030 tube axial fan (ATA) with a 3 HP motor (motor sold separately; performance shown is with the 3 HP motor this fan is built for). Fan speed 1077-1413 RPM, adjustable with the variable-pitch motor sheave. Sound 70-84 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e10,925 – 14,360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e9,650 – 13,430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e8,860 – 12,910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e7,960 – 12,340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e7,800* – 11,080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e8,400* – 9,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":32879401205783,"sku":"ATA-30-030","price":3629.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ATA.jpg?v=1586828007"},{"product_id":"18-tube-axial-paint-booth-fan-1025-1502-rpm","title":"18 Inch 1\/2 HP Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions ATA-18-005","description":"\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 1\/2HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"203\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"158\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-18\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e18.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e19.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e21.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e18\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-18-005 tube axial fan (ATA) with a 1\/2 HP motor (motor sold separately; performance shown is with the 1\/2 HP motor this fan is built for). Fan speed 1112-1641 RPM, adjustable with the variable-pitch motor sheave. Sound 58-68 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e2,530 – 3,740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e1,835 – 3,325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e1,715 – 3,090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e2,085 – 2,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14158625177635,"sku":"ATA-18-005","price":2569.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_933f005e-4eb9-4c64-878b-352b5c6e81b4.png?v=1601574339"},{"product_id":"18-tube-axial-paint-booth-fan-1454-1931","title":"18 Inch 1 HP Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions ATA-18-010","description":"\u003ch3\u003e\u003cstrong\u003ePAINT BOOTH FANS - (fit for 1HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"203\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"158\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-18\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e18.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e19.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e21.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e18\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-18-010 tube axial fan (ATA) with a 1 HP motor (motor sold separately; performance shown is with the 1 HP motor this fan is built for). Fan speed 1600-2100 RPM, adjustable with the variable-pitch motor sheave. Sound 67-73 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e3,630 – 4,780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e3,225 – 4,480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e2,974 – 4,311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e2,690 – 4,130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e2,600* – 3,730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e3,260*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14158625341475,"sku":"ATA-18-010","price":2629.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_dda45857-5bcf-40a4-bba5-764983ccabcc.png?v=1601574344"},{"product_id":"30-tube-axial-paint-booth-fan-1425-1760-rpm","title":"30 Inch 5 HP Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions ATA-30-050","description":"\u003ch3 data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 5HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-30\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e30.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e32.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e33.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e22.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-30-050 tube axial fan (ATA) with a 5 HP motor (motor sold separately; performance shown is with the 5 HP motor this fan is built for). Fan speed 1358-1672 RPM, adjustable with the variable-pitch motor sheave. Sound 75-88 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e13,800 – 17,005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e12,830 – 16,235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e12,270 – 15,810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e11,670 – 15,365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e10,320 – 14,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e8,500 – 13,340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e10,000* – 12,115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5\"\u003c\/td\u003e\n\u003ctd\u003e10,580*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14158626029603,"sku":"ATA-30-050","price":3659.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_f4a237ba-27ee-4eb5-9211-f5e690077f08.png?v=1601574350"},{"product_id":"42-tube-axial-paint-booth-fan-1206-1444-rpm","title":"42 Inch 10 HP Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions ATA-42-100","description":"\u003ch3 data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 10HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-42\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e42.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e44.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e45.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e22.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-42-100 tube axial fan (ATA) with a 10 HP motor (motor sold separately; performance shown is with the 10 HP motor this fan is built for). Fan speed 1158-1454 RPM, adjustable with the variable-pitch motor sheave. Sound 77-86 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e26,890 – 33,790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e25,315 – 32,570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e24,410 – 31,890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e23,415 – 31,185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e21,230 – 29,650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e18,545 – 27,955\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e16,650* – 26,150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5\"\u003c\/td\u003e\n\u003ctd\u003e18,850* – 22,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" alt=\"\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14158626848803,"sku":"ATA-42-100","price":5349.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_ebe2ee40-05f4-40f2-a66d-a989f65ec42a.png?v=1601574355"},{"product_id":"18-tube-axial-paint-booth-fan-880-1290-rpm","title":"18 Inch Tube Axial Paint Booth Exhaust Fan Less Motor - Global Finishing Solutions GFA-18VP-003","description":"\u003ch3\u003e\u003cstrong\u003e18\" TUBE AXIAL EXHAUST FANS (GFA MODELS)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cgoogle-sheets-html-origin\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003c\/google-sheets-html-origin\u003e\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e19-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e20-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-18VP-003 tube axial fan with a 1\/3 HP motor (motor sold separately; performance shown is with the 1\/3 HP motor this fan is built for). Fan speed 1228-1332 RPM, adjustable with the variable-pitch motor sheave. Sound 72-74 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e2,610 – 2,831\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e1,304 – 1,608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Sound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cdiv class=\"col-6 specs__cell specs__cell--label\"\u003e\u003cstrong\u003eManufacturer Warranty: 12 Months\u003c\/strong\u003e\u003c\/div\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14160405332003,"sku":"GFA-18VP-003","price":1619.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/Screenshot2023-06-05at11.10.06PM_8603384e-f3f4-4254-a057-2a5bea2643d8.png?v=1685978132"},{"product_id":"18-tube-axial-paint-booth-fan-1263-1740-rpm","title":"18 Inch Tube Axial Paint Booth Exhaust Fan Less Motor for 3\/4 HP Motor - Global Finishing Solutions ATA-18-007","description":"\u003ch3\u003e\u003cstrong\u003ePAINT BOOTH FANS - (fit for 3\/4HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"203\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"158\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-18\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e18.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e19.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e21.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e18\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-18-007 tube axial fan (ATA) with a 3\/4 HP motor (motor sold separately; performance shown is with the 3\/4 HP motor this fan is built for). Fan speed 1260-1860 RPM, adjustable with the variable-pitch motor sheave. Sound 61-72 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e2,875 – 4,241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e2,290 – 3,890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e1,900 – 3,685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e2,135 – 3,460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e2,505* – 2,965\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14160405430307,"sku":"ATA-18-007","price":2599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_e1b7058b-dcf4-4c1b-853a-85774a082e5e.png?v=1601577172"},{"product_id":"24-tube-axial-paint-booth-fan-924-1353-rpm","title":"24 Inch Tube Axial Paint Booth Exhaust Fan Less Motor for 3 HP Motor - Global Finishing Solutions ATA-24-030","description":"\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 3HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-selected=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eATA-24\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e24.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e25.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e27.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e19.50\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-24-030 tube axial fan (ATA) with a 3 HP motor (motor sold separately; performance shown is with the 3 HP motor this fan is built for). Fan speed 1543-1971 RPM, adjustable with the variable-pitch motor sheave. Sound 72-80 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e8,650 – 11,040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e7,930 – 10,495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e7,525 – 10,205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e7,085 – 9,900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e6,095 – 9,240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e6,035* – 8,525\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e6,905* – 7,700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14160405725219,"sku":"ATA-24-030","price":2949.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_fc0a8c2d-afbb-4b99-8228-1820e8d0fcb2.png?v=1601577178"},{"product_id":"30-tube-axial-paint-booth-fan-1179-1502-rpm","title":"30 Inch Tube Axial Paint Booth Exhaust Fan Less Motor for 5 HP Motor - Global Finishing Solutions GFA-30VP-050","description":"\u003ch3\u003e\u003cstrong\u003e30\" TUBE AXIAL EXHAUST FANS (GFA MODELS)For the 5HP Motor\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e31 3\/4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e 33”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-30VP-050 tube axial fan with a 5 HP motor (motor sold separately; performance shown is with the 5 HP motor this fan is built for). Fan speed 971-1197 RPM, adjustable with the variable-pitch motor sheave. Sound 87-92 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e12,379 – 15,357\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e11,469 – 14,617\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e10,810 – 14,211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e10,131 – 13,725\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e8,322 – 12,615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e7,898* – 11,349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e8,345* – 9,377\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14160406675491,"sku":"GFA-30VP-050","price":2639.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_edab0372-494f-4eeb-a4b7-a0cfdac1fc7b.png?v=1593618668"},{"product_id":"48-tube-axial-paint-booth-fan-951-1138-rpm","title":"48 Inch Tube Axial Paint Booth Exhaust Fan Less Motor for 10 HP Motor - Global Finishing Solutions ATA-48-100","description":"\u003ch3 data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 10HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-48\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e48.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e50.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e51.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e24.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-48-100 tube axial fan (ATA) with a 10 HP motor (motor sold separately; performance shown is with the 10 HP motor this fan is built for). Fan speed 820-1009 RPM, adjustable with the variable-pitch motor sheave. Sound 81-86 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e32,770 – 40,371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e29,790 – 38,031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e27,980 – 36,695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e26,020 – 35,255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e21,660 – 32,110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e22,000* – 29,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e24,760*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" alt=\"\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14160411525155,"sku":"ATA-48-100","price":6249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_a7734b9f-f7a7-4098-afaa-b90e29b5df5d.png?v=1601577186"},{"product_id":"12-tube-axial-paint-booth-fan","title":"Global Finishing Solutions ATA-12-007 12 Inch Tube Axial Paint Booth Fan Less Motor","description":"\u003ch3\u003e\u003cstrong\u003ePAINT BOOTH FANS - (fit for 3\/4HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eATA-12\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e12.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e13.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e14.88\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e18\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-12-007 tube axial fan (ATA) with a 3\/4 HP motor (motor sold separately; performance shown is with the 3\/4 HP motor this fan is built for). Fan speed 2043-3016 RPM, adjustable with the variable-pitch motor sheave. Sound 65-76 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e1,355 – 1,985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e1,180 – 1,885\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e1,075 – 1,830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e950 – 1,770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e960 – 1,630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e1,145* – 1,460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e1,085* – 1,245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14161309696035,"sku":"ATA-12-007","price":2549.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2.png?v=1601578514"},{"product_id":"24-tube-axial-paint-booth-fan-1154-1533-rpm","title":"Global Finishing Solutions ATA-24-020 24 Inch Tube Axial Paint Booth Fan Less Motor","description":"\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 2HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e \u003ccol width=\"203\" data-mce-fragment=\"1\"\u003e \u003ccol width=\"158\" data-mce-fragment=\"1\"\u003e \u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-24\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e24.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e25.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e27.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e19.50\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-24-020 tube axial fan (ATA) with a 2 HP motor (motor sold separately; performance shown is with the 2 HP motor this fan is built for). Fan speed 1182-1561 RPM, adjustable with the variable-pitch motor sheave. Sound 66-75 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e6,590 – 8,725\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e5,630 – 8,040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e5,035 – 7,645\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e4,280 – 7,215\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e5,270* – 6,250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14161310351395,"sku":"ATA-24-020","price":2919.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_e7523ed8-3a03-485e-9a1e-680a6852d0a5.png?v=1601578518"},{"product_id":"42-tube-axial-paint-booth-fan-1060-1299-rpm","title":"Global Finishing Solutions ATA-42-075 42 Inch Tube Axial Paint Booth Fan Less Motor","description":"\u003ch3 data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 7.5HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-42\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e42.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e44.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e45.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e22.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-42-075 tube axial fan (ATA) with a 7 1\/2 HP motor (motor sold separately; performance shown is with the 7 1\/2 HP motor this fan is built for). Fan speed 1096-1349 RPM, adjustable with the variable-pitch motor sheave. Sound 75-87 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e25,445 – 31,345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e23,765 – 30,015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e22,780 – 28,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e21,700 – 28,490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e19,310 – 26,760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e16,060 – 24,870\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e16,650* – 22,680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5\"\u003c\/td\u003e\n\u003ctd\u003e19,970*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":14161314185251,"sku":"ATA-42-075","price":5249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_012494aa-cd53-4289-bb86-e760961b2d3b.png?v=1601578525"},{"product_id":"18-tube-axial-paint-booth-fan-less-motor","title":"18 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-18VP-005","description":"\u003ch3\u003e\u003cstrong\u003e18\" TUBE AXIAL EXHAUST FANS (GFA MODELS) \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e19-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e20-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-18VP-005 tube axial fan with a 1\/2 HP motor (motor sold separately; performance shown is with the 1\/2 HP motor this fan is built for). Fan speed 1437-1541 RPM, adjustable with the variable-pitch motor sheave. Sound 76-78 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e3,054 – 3,275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e1,940 – 2,282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e1,430 – 1,703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627441733655,"sku":"GFA-18VP-005","price":1649.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/Screenshot2023-06-05at11.10.06PM_2a251909-4346-4926-ac6b-659d46bb8b9a.png?v=1685978257"},{"product_id":"18-tube-axial-paint-booth-fan-less-motor-1","title":"18 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-18VP-007","description":"\u003ch3\u003e\u003cstrong\u003e18\" TUBE AXIAL EXHAUST FANS (GFA MODELS) \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements. \u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e19-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e20-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-18VP-007 tube axial fan with a 3\/4 HP motor (motor sold separately; performance shown is with the 3\/4 HP motor this fan is built for). Fan speed 1437-1854 RPM, adjustable with the variable-pitch motor sheave. Sound 76-82 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e3,054 – 3,941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e1,940 – 3,326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e1,430 – 2,686\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e1,618* – 2,187\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627442028567,"sku":"GFA-18VP-007","price":1669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/Screenshot2023-06-05at11.10.06PM_31e92c24-228e-4255-9e3e-30842e4983e2.png?v=1685978496"},{"product_id":"18-tube-axial-paint-booth-fan-less-motor-2","title":"18 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-18VP-010","description":"\u003ch3\u003e\u003cstrong\u003e18\" TUBE AXIAL EXHAUST FANS (GFA MODELS) \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.=\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e19-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e20-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-18VP-010 tube axial fan with a 1 HP motor (motor sold separately; performance shown is with the 1 HP motor this fan is built for). Fan speed 1593-2116 RPM, adjustable with the variable-pitch motor sheave. Sound 78-85 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e3,386 – 4,498\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e2,461 – 4,081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e1,857 – 3,570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e1,748* – 3,021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e1,700* – 2,231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627442126871,"sku":"GFA-18VP-010","price":1689.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/Screenshot2023-06-05at11.10.06PM_9c1a643b-4e43-4430-b1c2-db026221bc8b.png?v=1685978507"},{"product_id":"18-tube-axial-paint-booth-fan-less-motor-3","title":"18 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-18VP-020","description":"\u003ch3\u003e\u003cstrong\u003e18\" TUBE AXIAL EXHAUST FANS (GFA MODELS) \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e19-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e20-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-18VP-020 tube axial fan with a 2 HP motor (motor sold separately; performance shown is with the 2 HP motor this fan is built for). Fan speed 2116-2638 RPM, adjustable with the variable-pitch motor sheave. Sound 85-90 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e4,498 – 5,607\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e4,081 – 5,273\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e3,570 – 5,106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e3,021 – 4,754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e2,231 – 3,851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e2,833* – 3,140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627442389015,"sku":"GFA-18VP-020","price":1709.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/Screenshot2023-06-05at11.10.06PM_51f5297f-06de-4ebf-93e2-695526e9ef23.png?v=1685978517"},{"product_id":"24-tube-axial-paint-booth-fan-less-motor","title":"24 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-24VP-010","description":"\u003ch3\u003e\u003cstrong\u003e24\" TUBE AXIAL EXHAUST FANS (GFA MODELS) \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e19-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e20-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-24VP-010 tube axial fan with a 1 HP motor (motor sold separately; performance shown is with the 1 HP motor this fan is built for). Fan speed 1437-1541 RPM, adjustable with the variable-pitch motor sheave. Sound 82-84 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e5,691 – 6,102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e5,142 – 5,610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e4,796 – 5,288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e4,353 – 4,966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e3,866*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627519033367,"sku":"GFA-24VP-010","price":2949.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_49d2c352-2062-40f1-8bbe-8f72d0c0f5f1.png?v=1593619047"},{"product_id":"24-tube-axial-paint-booth-fan-less-motor-1","title":"24 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-24VP-020","description":"\u003ch3\u003e\u003cstrong\u003e24\" TUBE AXIAL EXHAUST FANS (GFA MODELS) \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-24VP-020 tube axial fan with a 2 HP motor (motor sold separately; performance shown is with the 2 HP motor this fan is built for). Fan speed 1593-2011 RPM, adjustable with the variable-pitch motor sheave. Sound 85-90 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e6,308 – 7,964\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e5,842 – 7,669\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e5,531 – 7,422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e5,334 – 7,175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e4,225 – 6,681\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e4,621* – 6,019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e4,294* – 5,141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627519066135,"sku":"GFA-24VP-020","price":2149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_0d4d6281-ffbb-4929-93d8-474a1599af9c.png?v=1593619052"},{"product_id":"24-tube-axial-paint-booth-fan-less-motor-2","title":"24 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-24VP-030","description":"\u003ch3\u003e\u003cstrong\u003e24\" TUBE AXIAL EXHAUST FANS (GFA MODELS) \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e19-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e20-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-24VP-030 tube axial fan with a 3 HP motor (motor sold separately; performance shown is with the 3 HP motor this fan is built for). Fan speed 1802-2220 RPM, adjustable with the variable-pitch motor sheave. Sound 88-93 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e7,136 – 8,791\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e6,763 – 8,550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e6,487 – 8,340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e6,212 – 8,116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e5,601 – 7,669\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e4,621 – 7,221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e4,294* – 6,545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627519229975,"sku":"GFA-24VP-030","price":2169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_070d52ad-a7bc-403f-a752-97cd3cad9cb1.png?v=1593619058"},{"product_id":"30-tube-axial-paint-booth-fan-less-motor","title":"30 Inch Tube Axial Paint Booth Fan Less Motor, for 2 HP Motor - Global Finishing Solutions GFA-30VP-020","description":"\u003ch3\u003e\u003cstrong\u003e30\" TUBE AXIAL EXHAUST FANS (GFA MODELS)- For the 2HP Motor\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e31 3\/4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e33”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-30VP-020 tube axial fan with a 2 HP motor (motor sold separately; performance shown is with the 2 HP motor this fan is built for). Fan speed 610-835 RPM, adjustable with the variable-pitch motor sheave. Sound 77-84 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e7,618 – 10,582\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e5,571 – 9,363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e4,150 – 8,596\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e5,427* – 7,579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627541282839,"sku":"GFA-30VP-020","price":2639.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_0f835c3d-be27-4db1-9b37-0577ca36942a.png?v=1593619063"},{"product_id":"34-tube-axial-paint-booth-fan-less-motor","title":"34 Inch Tube Axial Paint Booth Fan Less Motor, for 5 HP Motor - Global Finishing Solutions GFA-34VP-050","description":"\u003ch3\u003e\u003cstrong\u003e34\" TUBE AXIAL EXHAUST FANS (GFA MODELS) (for use w\/\u003cspan\u003e 5\u003c\/span\u003eHP Motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" style=\"width: 639px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' style=\"width: 357.969px;\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' style=\"width: 268.031px;\"\u003eGFA-34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' style=\"width: 357.969px;\"\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' style=\"width: 268.031px;\"\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' style=\"width: 357.969px;\"\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' style=\"width: 268.031px;\"\u003e34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' style=\"width: 357.969px;\"\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' style=\"width: 268.031px;\"\u003e35 3\/4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' style=\"width: 357.969px;\"\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' style=\"width: 268.031px;\"\u003e 37”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-34VP-050 tube axial fan with a 5 HP motor (motor sold separately; performance shown is with the 5 HP motor this fan is built for). Fan speed 1108-1429 RPM, adjustable with the variable-pitch motor sheave. Sound 89-95 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e14,504 – 18,706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e13,265 – 17,746\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e12,232 – 17,265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e11,063 – 16,649\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e11,076* – 14,878\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e12,835*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627569659927,"sku":"GFA-34VP-050","price":3529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_b3ded42f-3bf7-441a-9c99-3528f718fceb.png?v=1593619067"},{"product_id":"34-tube-axial-paint-booth-fan-less-motor-1","title":"34 Inch Tube Axial Paint Booth Fan Less Motor, for 3 HP Motor - Global Finishing Solutions GFA-34VP-030","description":"\u003ch3\u003e\u003cstrong\u003e34\" TUBE AXIAL EXHAUST FANS (GFA MODELS) (for use w\/ 3HP Motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" style=\"width: 639px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' style=\"width: 357.969px;\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' style=\"width: 268.031px;\"\u003eGFA-34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' style=\"width: 357.969px;\"\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' style=\"width: 268.031px;\"\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' style=\"width: 357.969px;\"\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' style=\"width: 268.031px;\"\u003e34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' style=\"width: 357.969px;\"\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' style=\"width: 268.031px;\"\u003e35 3\/4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' style=\"width: 357.969px;\"\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' style=\"width: 268.031px;\"\u003e 37”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-34VP-030 tube axial fan with a 3 HP motor (motor sold separately; performance shown is with the 3 HP motor this fan is built for). Fan speed 979-1236 RPM, adjustable with the variable-pitch motor sheave. Sound 86-92 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e12,816 – 16,180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e11,248 – 15,069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e9,943 – 14,392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e9,851* – 13,373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e11,076*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627570020375,"sku":"GFA-34VP-030","price":3529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_564b9829-84d2-4ddd-a9a9-d7e5443fac43.png?v=1593619072"},{"product_id":"34-tube-axial-paint-booth-fan-less-motor-2","title":"34 Inch Tube Axial Paint Booth Fan Less Motor, for 2 HP Motor - Global Finishing Solutions GFA-34VP-020","description":"\u003ch3\u003e\u003cstrong\u003e34\" TUBE AXIAL EXHAUST FANS (GFA MODELS)(for use w\/ 2HP Motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e35 3\/4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e 37”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-34VP-020 tube axial fan with a 2 HP motor (motor sold separately; performance shown is with the 2 HP motor this fan is built for). Fan speed 915-1108 RPM, adjustable with the variable-pitch motor sheave. Sound 84-87 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e11,978 – 14,504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e10,164 – 13,265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e8,740 – 12,232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e9,851* – 11,063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627570184215,"sku":"GFA-34VP-020","price":3529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_a84fa356-7108-48e5-80b5-5ee5c6adc45a.png?v=1593619078"},{"product_id":"40-tube-axial-paint-booth-fan-less-motor","title":"40 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-40VP-050","description":"\u003ch3\u003e\u003cstrong\u003e40\" TUBE AXIAL EXHAUST FANS (GFA MODELS)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e40\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e41 3\/4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e43”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-40VP-050 tube axial fan with a 5 HP motor (motor sold separately; performance shown is with the 5 HP motor this fan is built for). Fan speed 915-1140 RPM, adjustable with the variable-pitch motor sheave. Sound 87-93 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e21,163 – 26,367\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e18,374 – 24,197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e16,364 – 23,032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e13,626 – 21,693\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e15,746* – 17,392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627591483415,"sku":"GFA-40VP-050","price":3529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_6f1e8ad2-aa19-49d1-b896-e024efc8cf77.png?v=1593619083"},{"product_id":"40-tube-axial-paint-booth-fan-less-motor-1","title":"40 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-40VP-075","description":"\u003ch3\u003e\u003cstrong\u003e40\" TUBE AXIAL EXHAUST FANS (GFA MODELS)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"203\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e40\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e41 3\/4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e43”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-40VP-075 tube axial fan with a 7 1\/2 HP motor (motor sold separately; performance shown is with the 7 1\/2 HP motor this fan is built for). Fan speed 937-1242 RPM, adjustable with the variable-pitch motor sheave. Sound 88-95 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e21,672 – 28,726\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e18,974 – 26,734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e17,189 – 25,738\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e14,424 – 24,553\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003eup to 21,157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31627592957975,"sku":"GFA-40VP-075","price":3529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_5d390692-5e34-440e-af69-165a40123d5e.png?v=1593619088"},{"product_id":"30-tube-axial-paint-booth-fan-less-motor-1","title":"30 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions GFA-30VP-030","description":"\u003ch3\u003e\u003cstrong\u003e30\" TUBE AXIAL EXHAUST FANS (GFA MODELS) For the 3HP Motor\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGFA models of GFS’ tube axial fans feature continuously welded housing for an airtight seal. The propellers are non-sparking cast aluminum, providing consistent air velocity at higher static pressures. The universal motor plates allow for adjustable belt tensioning. The bearings are of premium air handling quality, self-aligning and have an L10 life of 40,000 hours. The belt guard provides protection from the rotating pulley, per OSHA requirements.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"203\"\u003e\n\u003ccol width=\"158\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eGFA-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Ring to Ring\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC. Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e31 3\/4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e33”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS GFA-30VP-030 tube axial fan with a 3 HP motor (motor sold separately; performance shown is with the 3 HP motor this fan is built for). Fan speed 700-926 RPM, adjustable with the variable-pitch motor sheave. Sound 80-86 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e8,804 – 11,760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e7,217 – 10,828\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e5,979 – 10,078\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e5,427* – 9,377\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e6,959*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Sound data obtained under laboratory conditions. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/gl1_480x480.png?v=1593524969\" alt=\"\"\u003e\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSound level data given in the fan chart was obtained under laboratory conditions. It is not likely that these results will permit determination of sound power in all site conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eData published in this chart may be used for the following purposes:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComparison of fans that are similar in type and size.\u003c\/li\u003e\n\u003cli\u003eScaling down fan noise from one size and speed to another size and speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDepending on the application, configuration of the apr duct, attention characteristics of material used, and acoustical condition, etc., the reduction in dB will vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Warranty:\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/strong\u003e\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":31685454495767,"sku":"GFA-30VP-030","price":2639.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/gl3_10d4b483-2457-417c-83dc-5408979c4bfa.png?v=1628804076"},{"product_id":"18-tube-axial-paint-booth-fan-less-motor-4","title":"18 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions ATA-18-020","description":"\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS - (fit for 2HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"203\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"158\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-18\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e18.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e19.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e21.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e18\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-18-020 tube axial fan (ATA) with a 2 HP motor (motor sold separately; performance shown is with the 2 HP motor this fan is built for). Fan speed 2015-2545 RPM, adjustable with the variable-pitch motor sheave. Sound 72-79 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e4,585 – 9,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e4,270 – 5,550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e4,090 – 5,420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e3,900 – 5,280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e3,480 – 4,985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e2,930 – 4,660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e3,650* – 4,300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5\"\u003c\/td\u003e\n\u003ctd\u003e3,895*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":32872954822679,"sku":"ATA-18-020","price":2659.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_32b21981-b93c-4d0a-8f79-7777fb4b7cb9.png?v=1601610428"},{"product_id":"36-tube-axial-paint-booth-fan-less-motor","title":"36 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions ATA-36-050","description":"\u003ch3 data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 5HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}'\u003ePart no.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}'\u003eATA-36\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}'\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}'\u003e36.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}'\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}'\u003e38.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}'\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}'\u003e39.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}'\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}'\u003e22.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-36-050 tube axial fan (ATA) with a 5 HP motor (motor sold separately; performance shown is with the 5 HP motor this fan is built for). Fan speed 1116-1370 RPM, adjustable with the variable-pitch motor sheave. Sound 72-81 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e18,160 – 22,320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e16,495 – 21,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e15,500 – 20,260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e14,430 – 19,470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e11,890 – 17,740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e12,700* – 15,790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e13,460*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":32879542173719,"sku":"ATA-36-050","price":4649.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_a77cc4c6-ad56-4efa-b7f9-a37fc52ffcd7.png?v=1601610551"},{"product_id":"36-tube-axial-paint-booth-fan-less-motor-1","title":"36 Inch Tube Axial Paint Booth Fan Less Motor - Global Finishing Solutions ATA-36-075","description":"\u003ch3 data-mce-fragment=\"1\"\u003ePAINT BOOTH FANS (fit for 7.5HP Single Phase\/Three Phase \u0026amp; Standard\/Explosion proof motor)\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eTUBE AXIAL EXHAUST FANS (ATA MODELS)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGFS’ tube axial fans are the ideal choice for installations with straight-through airflow in ducted or non-ducted systems. The tube axial fans are designed for commercial and industrial applications in which low to medium air volumes are required at lower pressures. Units come pre-assembled and include variable-pitch motor sheaves for maximum operating efficiency and on-site adjustment.\u003c\/p\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Part no.\"}' data-mce-fragment=\"1\"\u003ePart no.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"GFA-18\"}' data-mce-fragment=\"1\"\u003eATA-36\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"A. Ring to Ring\"}' data-mce-fragment=\"1\"\u003eA. Inside Dim\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"30\\\"\"}' data-mce-fragment=\"1\"\u003e36.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"B. Inside Dim\"}' data-mce-fragment=\"1\"\u003eB.  Mounting Bolt\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"18\\\"\"}' data-mce-fragment=\"1\"\u003e38.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C. Mounting Bolt\"}' data-mce-fragment=\"1\"\u003eC.Outside Dim.\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-1\/4\\\"\"}' data-mce-fragment=\"1\"\u003e39.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"D. Outside Dim.\"}' data-mce-fragment=\"1\"\u003eD. Ring to Ring \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20-1\/2\\\"\"}' data-mce-fragment=\"1\"\u003e22.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- pse-fan-perf --\u003e\n\u003ch3\u003eFan Performance: CFM at Static Pressure\u003c\/h3\u003e\n\u003cp\u003eGFS ATA-36-075 tube axial fan (ATA) with a 7 1\/2 HP motor (motor sold separately; performance shown is with the 7 1\/2 HP motor this fan is built for). Fan speed 1228-1541 RPM, adjustable with the variable-pitch motor sheave. Sound 77-83 dBA at 5 ft.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStatic pressure (in. w.c.)\u003c\/th\u003e\n\u003cth\u003eAirflow (CFM)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air (0\")\u003c\/td\u003e\n\u003ctd\u003e19,995 – 25,120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.25\"\u003c\/td\u003e\n\u003ctd\u003e18,500 – 23,960\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.375\"\u003c\/td\u003e\n\u003ctd\u003e17,650 – 23,320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\"\u003c\/td\u003e\n\u003ctd\u003e16,710 – 22,650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75\"\u003c\/td\u003e\n\u003ctd\u003e14,660 – 21,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0\"\u003c\/td\u003e\n\u003ctd\u003e12,110 – 19,625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"\u003c\/td\u003e\n\u003ctd\u003e14,525* – 17,875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5\"\u003c\/td\u003e\n\u003ctd\u003e15,810*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eEach CFM range runs from the slowest to the fastest sheave setting. * Lowest CFM the fan can run at that static pressure (the fan curve is unstable below it). Pressures not listed are outside this fan's rating. Installation type B (free inlet, ducted outlet); power rating does not include drive losses or appurtenances in the airstream; AMCA certified for air performance. Source: Global Finishing Solutions accessory catalog.\u003c\/small\u003e\u003c\/p\u003e\n\u003c!-- \/pse-fan-perf --\u003e\n\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\" alt=\"\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ata1_480x480.png?v=1599592117\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePerformance shown is for installation type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. This product is certified to bear the AMCA seal for air performance.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSound pressure range listed is A-weighted at a distance of 5 feet from the fan with a directivity factor of Q=2 (hemispherical radiation) and has been tested per AMCA standard 303. The range covers the minimum and maximum air performance points shown. Lowest sound pressure level is for the lowest airflow rate (CFM) at the lowest static pressure (SP). Highest sound pressure level is for the highest airflow rate (CFM) at the highest static pressure (SP).\u003c\/p\u003e","brand":"Global Finishing Solutions","offers":[{"title":"Default Title","offer_id":32879600926743,"sku":"ATA-36-075","price":4699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/products\/ata2_7058714b-0070-43aa-9d72-25698c0c54cc.png?v=1601610579"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/collections\/fanmotor_1319bf41-100f-4654-9b46-83fc43bd704e.jpg?v=1604668471","url":"https:\/\/liamemporiumvg.shop\/collections\/explosion-proof-paint-booth-fan-motors.oembed","provider":"Pittsburgh Spray","version":"1.0","type":"link"}